2017年1月11日星期三

How to use the submersible pump


1, mining submersible pump can not dehydration operation. If you want to test in anhydrous conditions, not more than 5 minutes. In the pumping process, when the water level declining, we must pay attention to the pump can not be exposed to the surface work.
2, mining submersible pump can not be restarted immediately after shutdown, the tube must wait for the water after the return before they can start. If after starting can not water, should immediately shut down to identify the reasons, be excluded.
3, should be used in accordance with the provisions of the lift; supporting rubber tube, tube or canvas tube diameter should meet the technical requirements.
4, fire submersible pump into the water or raised the surface, you must pull the lifting rope, absolutely can not pull the cable. To carry, disassemble or repair, should first cut off the power.
5, the fire submersible pump submersible depth of 0.5 to 3.0 meters, submersible pump submerged in water, it should be lifted vertically, not recumbent, but can not fall into the mud.
6, submersible pumps shall not be used for irrigation and drainage of high sediment or mud water, not too frequent start. When the pump can be used outside the bamboo net or wire trillion trillion live, to prevent water weed stuck pump impeller or plug the submersible pump grid.
7, boot, if the impeller reversal, should immediately stop, and then replace the cable in the three-phase core of any two-phase, so that is transferred out of water.
8, submersible sewage pump can be used to control the pump control cabinet. In the absence of such equipment, a three-phase knife switch may be used, provided that an electric fuse of 6 amps is provided.

2017年1月8日星期日

Vertical deep well pump characteristics


(A) vertical deep well pump structure
Deep well pump device consists of pump working parts, pump tube, drive shaft, pump seat and drive motor (deep well pump with three-phase asynchronous motor) and so on, for pumping deep underground water. It is the main difference with the submersible pump, submersible pump is submersible pumps and submersible pumps directly assembled into the unit, or by the submersible motor shaft extension directly into the pump components to form a pump-one product; the history of deep well pump device Of the motor and the pump is installed separately, the middle through a long axis together: the working parts of the pump installed in the ground with a certain aperture of the well, the drive motor - deep well pump with three-phase asynchronous motor installed in the well The tube is driven by the long axis on the ground other than the tube.
(B) vertical deep well pump characteristics
Vertical deep well pump is characterized by the diameter of the pump by the strict restrictions on the size of the pump is slender, the higher the lift, the pump more series, the rated head changes by increasing or decreasing the pump series to adjust, this feature Similar to the use of submersible pumps for wells. It drives the motor to work on the ground, the diameter size from the well diameter restrictions, nor affected by well water. But the motor and pump work between the power transmission components rely on multi-level long axis transmission, loss larger. When the pump working parts are installed deep, the shaft is very long (up to 80 ~ 100m above), the drive shaft is prone to failure.
(C) the motor phase sequence determination and anti-reverse device


As the deep shaft pump pump shaft and drive shaft are used threaded connection, when the normal operation of deep well pump (from the motor overlooking the top down for the counter-clockwise), the drive shaft and the pump pipe thread are in a tight state. However, when the deep well pump is installed for trial operation, if the connection between the motor and the power supply is determined according to the specified procedure, the motor rotation may be reversed, resulting in a short reversal of the start of the deep well pump, And the pump pipe connections have a bad effect; in the deep well pump operation, when the pump from normal operation state into the stop state, the pump tube in the water column due to the role of gravity downward flow, impulse pump impeller, will deep wells Reverse rotation of the pump will also affect the drive shaft and pump pipe connection screw loose, thus affecting the reliability of threaded connections. For this reason, from the guarantee pump tubing and drive shaft thread connection reliability, thus guarantees the deep well pump the movement security to start, in the vertical deep well pump electric motor installs the anti-reverse installment, guarantees the deep well water pump at any moment not Reversing, thereby fundamentally eliminating the possibility of screw connection loosening.

Code for installation of hot water submersible pumps

Code for installation of hot water submersible pumps